
BPL Cortex RADS-AI Smarter Reporting, Built Into Your Radiography Workflow
Pair your H-RAD system with an AI layer that works the moment an image is acquired.
BPL Cortex RADS-AI is an AI-powered software platform that integrates with BPL's Digital Radiography systems — including the H-RAD 32/40*/50** — to automatically triage chest X-rays as normal or abnormal, highlight key findings directly on the image, and generate a structured draft report for radiologist review. Because AI models run locally on-device, analysis happens in real time without internet dependency, keeping reporting fast and patient data inside your own infrastructure.
Built to Keep Whole-BodyImaging Moving.
-
Two Detectors, One Continuous Workflow
Because the table and wall bucky stand each have their own fixed 17x17-inch CsI detector, technologists can move a patient from a recumbent table study to an upright chest or extremity view without physically relocating a detector panel — reducing setup time between exposures.

-
Power Sized to Your Department
The 32, 40*, and 50** kW variants let a facility choose generator output based on actual case volume — from routine diagnostic-centre workloads up to higher-throughput hospital radiology departments — without changing the underlying system architecture.

-
Simplified Site Planning
The ceiling-free, floor-mounted stand design reduces dependency on structural ceiling-mount infrastructure, which can simplify installation timelines and site preparation, particularly in retrofit environments.

-
Broad Clinical Coverage
A single system configuration supports skull, chest, spine, abdomen, and extremity imaging, making it suited to general-purpose radiology departments rather than a single specialised use case.

-
Built on a Proven Platform
The H-RAD 32/40/50 generator and rotating-anode tube architecture is shared across BPL's DR-1 and DR-2 Prime series, reflecting an established design platform rather than a first-generation system.

Built for Specific Clinical Use
Designed for departments handling consistent, high-volume general radiography.

Diagnostic Centres
Dual-detector setup supports faster patient turnover by removing detector-swap downtime between table and wall studies.
Government & Multi-Speciality Hospitals
Scales across 32/40/50 kW variants to match departmental patient load and procedure mix.
Corporate Hospitals
Floor-mounted, ceiling-free design simplifies installation in both new-build and retrofit radiology suites.
Orthopaedic & Trauma Units
Wall bucky and table detector combination supports extremity, spine, and skeletal imaging without repositioning a single detector.
Emergency & General Radiology
High-frequency generator output supports rapid acquisition across a broad range of body habitus and exposure needs.
Technical Specifications
Essential details for procurement teams, biomedical engineers, and dealers.
-
SpecificationDetails
-
SeriesDR-2 Prime
-
Power Rating32 kW / 40 kW* / 50 kW**
-
mA Rating400 mA / 500 mA* / 650 mA**
-
X-Ray TubeRotating anode tube, high-frequency generator
-
Detector ConfigurationDual 17x17-inch CsI Flat Panel Detectors (table + wall bucky)
-
Stand TypeFloor-mounted, ceiling-free
-
Table TypeFloating-top radiography table
-
Wall UnitWall bucky DR stand
-
RegulatoryAERB compliant; ISO 13485:2016 & ISO 9001:2015 certified manufacturing
-
Recommended SettingsDiagnostic centres, government & multi-speciality hospitals, corporate hospitals, medical institutions
Full technical specification sheet available on request.
See the Product in Use
Compare Similar Products
Not sure if this is the right configuration? Compare it with other systems in BPL's range.
-
BPL H-RAD 32 / 40* / 50**
Floor-mounted dual-detector digital radiography system for high-volume, whole-body imaging.
- Best for: High-volume, whole-body imaging with table and wall studies in one room.
- Detector Configuration: Dual 17x17-inch CsI (table + wall bucky), floor-mounted, ceiling-free.
- Power Range: 32 / 40* / 50** kW
Current Model -
BPL H-RAD 32 / 32i
Single-detector digital radiography system for single-room diagnostic centres and lower-volume departments.
- Best for: Single-room diagnostic centres, lower-volume departments.
- Detector Configuration: Single 17x17-inch CsI, mobile table-mounted.
- Power Range: 32 kW.
-
BPL H-RAD 40 / 50*
Single-detector digital radiography system for whole-body general radiography at moderate volume.
- Best for: whole-body general radiography, moderate volume.
- Detector Configuration: Single 17x17-inch CsI, mobile table-mounted.
- Power Range: 40/50 kW
-
BPL M-RAD 5.0 DR
Power Rating: 5 kW · mA Range: Up to 100
- Best for: mobile bedside imaging — wards, ICU, OT, emergency.
- Detector Configuration: Single portable detector.
- Power Range: N/A (mobile, ultra-high-frequency).
Product Support You Can Depend On
Get product assistance, demo support, installation guidance, and service information directly from BPL Medical Technologies.
FAQs About BPL H-RAD 32 / 40* / 50**
It is a floor-mounted fixed digital radiography system used for whole-body general radiography, including skull, chest, spine, abdomen, and extremity imaging, in diagnostic centres and hospital radiology departments.
The three variants share the same DR-2 Prime architecture. They differ by generator output: 32 kW / 400 mA, 40 kW* / 500 mA*, and 50 kW** / 650 mA**. Choose output for case volume, from routine diagnostic-centre work up to higher-throughput hospital radiology, without changing the rest of the system.
DR-2 Prime is a dual-detector, floor-mounted configuration: a 17"x17" CsI detector in the table and a second in the wall bucky, so table and upright studies do not require moving a panel. DR-1 Prime uses a single 17"x17" CsI detector with a mobile radiography table and is positioned for lower-volume diagnostic settings. The H-RAD 32/40/50 generator and rotating-anode tube architecture is shared across both series.
No. The system is designed with an ergonomic floor-mounted stand that uses electromagnetic locks for tube and detector movement. This reduces the need for structural ceiling-mount infrastructure, making the system ideal for easier installation in compact or retrofit rooms.
Dual 17"x17" CsI flat panel detectors, one in the floating-top table and one in the wall bucky DR stand.
Yes. The mock positions it for consistent, high-volume general radiography. Dual detectors remove detector-swap downtime between table and wall studies, and the 32/40/50 kW choices scale with departmental load. Recommended settings include diagnostic centres, government and multi-speciality hospitals, corporate hospitals, and medical institutions.
Yes. The specification table lists AERB compliance, with manufacturing certified to ISO 13485:2016 and ISO 9001:2015.
Use [Request Demo] or [Request a Commercial Quotation] on the product page, or call the toll-free centre at 1800-425-2355 (9 am–8 pm, Monday through Saturday). You can also enquire at bplmedicaltechnologies.com/business-enquiry/ or email sales.medical@bpl.in.
Yes. BPL Cortex RADS-AI integrates with BPL Digital Radiography systems, including H-RAD 32/40*/50**. It triages chest X-rays as normal or abnormal, highlights findings on the image, and drafts a structured report for radiologist review. Models run locally on-device, so analysis does not depend on internet connectivity.
Compare with H-RAD 32/32i (DR-1 Prime) for single-room, lower-volume centres; H-RAD 40/50 (DR-1 Prime) for single-detector whole-body work at moderate volume; M-RAD 5.0 DR for mobile bedside imaging in wards, ICU, OT, and emergency; and EVS retrofit panels if the need is to digitise an existing analog or CR room rather than install a new fixed system.









