
BPL Cortex RADS-AI Smarter Reporting, Built Into Your Radiography Workflow
Pair your H-RAD system with an AI layer that works the moment an image is acquired.
BPL Cortex RADS-AI is an AI-powered software platform that integrates with BPL's Digital Radiography systems — including the H-RAD 40/50* — to automatically triage chest X-rays as normal or abnormal, highlight key findings directly on the image, and generate a structured draft report for radiologist review. Because AI models run locally on-device, analysis happens in real time without internet dependency, keeping reporting fast and patient data inside your own infrastructure.
Built for Moderate-Volume Whole-Body Imaging.
-
One Detector, Sized for General Radiography
A single 17x17-inch CsI flat panel detector, permanently housed for safety and paired with a mobile radiography table, supports whole-body general radiography at moderate volume — without the dual table-and-wall detector configuration of DR-2 Prime.

-
40 kW or 50 kW Output
Choose between 40 kW / 500 mA and 50 kW* / 650 mA* generator ratings on the same DR-1 Prime architecture. That higher output versus the 32 kW H-RAD 32/32i supports broader body habitus and busier single-detector rooms while keeping one mobile-table workflow.

-
Floor-Mounted Handling
An ergonomic floor-mount design with electromagnetic locks for tube and detector movement, plus a high-brightness LED collimator, supports precise positioning without ceiling-suspended tube-crane infrastructure.

-
Removable Grid, Full Connectivity
A removable grid and grid holder support technique flexibility across studies. The system is DICOM 3.0, HIS/RIS, and PACS compatible, with optional stitching software and stand for full-spine and scanogram imaging.

-
Shared Platform, Higher Single-Detector Capacity
The H-RAD generator and rotating-anode tube architecture is shared across BPL's DR-1 and DR-2 Prime series — this DR-1 Prime configuration focuses that platform on a single-detector room with 40/50 kW capacity for moderate-volume whole-body work.

Built for Specific Clinical Use
Designed for whole-body general radiography at moderate volume.

Whole-Body General Radiography
Single housed 17x17-inch detector and mobile table support skull, chest, spine, abdomen, and extremity imaging in a general-purpose radiology room.
Moderate-Volume Departments
40/50 kW output suits departments that outgrow a 32 kW single-detector room but do not yet need dual table-and-wall detectors for high-throughput turnover.
Diagnostic Centres & Hospital Radiology
Floor-mounted, mobile-table layout fits diagnostic centres and hospital general radiography suites specifying one detector per room.
Full-Spine & Scanogram (Optional)
Optional stitching software and stand enable display of the entire spine or lower extremities on a single image when that workflow is required.
New-Build & Retrofit Rooms
Floor-mounted design can simplify installation where dual-detector or ceiling-mounted infrastructure is not part of the room plan.
Technical Specifications
Essential details for procurement teams, biomedical engineers, and dealers.
-
SpecificationDetails
-
SeriesDR-1 Prime
-
Power Rating40 kW / 50 kW*
-
mAs Range500 mA / 650 mA*
-
X-Ray TubeRotating anode tube, imported high-frequency generator
-
Detector ConfigurationSingle 17x17-inch CsI Flat Panel Detector, permanently housed; mobile radiography table
-
Stand TypeErgonomic floor mount; electromagnetic locks for tube and detector movement
-
CollimatorHigh brightness LED collimator
-
GridRemovable grid and grid holder
-
ConnectivityDICOM 3.0, HIS/RIS, and PACS compatible
-
OptionalStitching software and stand for full-spine and scanogram
-
Recommended SettingsWhole-body general radiography; moderate-volume diagnostic centres and hospital radiology departments
Full technical specification sheet available on request.
See the Product in Use
Compare Similar Products
Not sure if this is the right configuration? Compare it with other systems in BPL's range.
-
BPL H-RAD 40 / 50*
Single-detector digital radiography system for whole-body general radiography at moderate volume.
- Best for: whole-body general radiography, moderate volume.
- Detector Configuration: Single 17x17-inch CsI, mobile table-mounted.
- Power Range: 40/50 kW
Current Model -
BPL H-RAD 32 / 32i
Single-detector digital radiography system for single-room diagnostic centres and lower-volume departments.
- Best for: Single-room diagnostic centres, lower-volume departments.
- Detector Configuration: Single 17x17-inch CsI, mobile table-mounted.
- Power Range: 32 kW.
-
BPL H-RAD 32 / 40* / 50**
Floor-mounted dual-detector digital radiography system for high-volume, whole-body imaging.
- Best for: High-volume, whole-body imaging with table and wall studies in one room.
- Detector Configuration: Dual 17x17-inch CsI (table + wall bucky), floor-mounted, ceiling-free.
- Power Range: 32 / 40* / 50** kW
-
BPL M-RAD 5.0 DR
Power Rating: 5 kW · mA Range: Up to 100
- Best for: mobile bedside imaging — wards, ICU, OT, emergency.
- Detector Configuration: Single portable detector.
- Power Range: N/A (mobile, ultra-high-frequency).
Product Support You Can Depend On
Get product assistance, demo support, installation guidance, and service information directly from BPL Medical Technologies.
FAQs About BPL H-RAD 40 / 50*
It is a floor-mounted fixed digital radiography system in the DR-1 Prime series, used for whole-body general radiography — including skull, chest, spine, abdomen, and extremity imaging — in diagnostic centres and hospital radiology departments at moderate volume.
Both share the same DR-1 Prime architecture: a single housed 17"x17" CsI detector and a mobile radiography table. They differ by generator output — 40 kW / 500 mA versus 50 kW* / 650 mA*. Choose the rating that matches case volume and patient mix.
DR-1 Prime, including H-RAD 40/50, uses a single 17"x17" CsI detector with a mobile radiography table and is positioned for whole-body general radiography at moderate volume. DR-2 Prime (H-RAD 32/40/50) is a dual-detector, floor-mounted configuration: a detector in the floating-top table and a second in the wall bucky, so table and upright studies do not require moving a panel. The H-RAD generator and rotating-anode tube architecture is shared across both series.
No. Stand type is an ergonomic floor mount with electromagnetic locks for tube and detector movement, which reduces dependency on structural ceiling-mount infrastructure and can simplify installation in new-build and retrofit rooms.
A single 17"x17" CsI flat panel detector, permanently housed for safety, with a mobile radiography table.
Both are DR-1 Prime single-detector systems with a mobile radiography table. H-RAD 32/32i is listed at 32 kW with mAs range up to 400, and is positioned for single-room, lower-volume departments. H-RAD 40/50 is listed at 40 kW / 50 kW* and 500 / 650* mA for whole-body general radiography at moderate volume. The 40/50 listing also includes HIS/RIS alongside DICOM 3.0 and PACS.
The system is DICOM 3.0, HIS/RIS, and PACS compatible. Optional stitching software and stand are available for full-spine and scanogram imaging.
Use [Request Demo] or [Request a Commercial Quotation] on the product page, or call the toll-free centre at 1800-425-2355 (9 am–8 pm, Monday through Saturday). You can also enquire at bplmedicaltechnologies.com/business-enquiry/ or email sales.medical@bpl.in.
Yes. BPL Cortex RADS-AI integrates with BPL Digital Radiography systems, including H-RAD 40/50*. It triages chest X-rays as normal or abnormal, highlights findings on the image, and drafts a structured report for radiologist review. Models run locally on-device, so analysis does not depend on internet connectivity.
Compare with H-RAD 32/32i (DR-1 Prime) for a lower-output single-detector room; H-RAD 32/40/50 (DR-2 Prime) for dual-detector, higher-volume rooms; M-RAD 5.0 DR for mobile bedside imaging in wards, ICU, OT, and emergency; and EVS retrofit panels if the need is to digitise an existing analog or CR room rather than install a new fixed system.









