Digital Mammography Built for Comfort and Clarity

  • Quick Scan Technology

    Enables pain-free screening and an efficient clinic workflow, with image acquisition typically within 10 to 15 seconds.

    Quick Scan Technology
  • Ergonomic Patient Positioning

    A compact design with ergonomic handles and a face shield for natural, comfortable positioning.

    Ergonomic Patient Positioning
  • Automated MLO Positioning

    Moves to the MLO position in a single click, so patients do not need repositioning during four-view examinations.

    Automated MLO Positioning
  • Pain-Free Compression

    Variable speed compression with a soft, curved-edge paddle for gentle, comfortable compressions.

    Pain-Free Compression
  • Wheelchair Access

    The system retracts to its lowest height and inclines forward, making screening comfortable for wheelchair-bound patients and capturing maximum breast tissue.

    Wheelchair Access
  • Low-Dose Gridless Technology

    Rejects scattered radiation without an anti-scatter grid, reducing patient dose and improving image resolution.

    Low-Dose Gridless Technology
  • High-Quality, DICOM-Compatible Images

    Compatible with latest-generation detectors for superior image quality and quick upload to hospital servers.

    High-Quality, DICOM-Compatible Images
  • Intuitive Workflow

    A feather-touch user interface and streamlined workflow simplify mammography examinations for operators.

    Intuitive Workflow

Where Lilac Fits Best

For hospitals and diagnostic centres building or expanding a dedicated breast imaging and screening service.

Where Lilac Fits Best

Breast Imaging Centres

High-quality, noise-free images for early detection and accurate diagnosis of breast conditions.

Hospital Radiology Departments

A dedicated digital mammography unit for screening and diagnostic mammography.

High-Volume Screening

Acquisition typically within 10 to 15 seconds and single-click MLO positioning keep patient throughput efficient.

Accessible Screening

Comfortable screening for wheelchair-bound patients, with the system lowered and inclined forward.

New Mammography Installations

A complete new digital mammography system, for facilities installing a unit rather than upgrading an existing room.

Technical Specifications

Essential details for procurement teams, biomedical engineers, and dealers.

  • Specification
    Details
  • Type
    Digital mammography unit
  • Model
    Lilac
  • Image Acquisition
    Typically within 10 to 15 seconds
  • Detector
    Wide detector for simultaneous screening of both breasts without increasing radiation dose
  • Scatter Rejection
    Gridless technology, with no anti-scatter grid
  • Compression
    Variable speed, with a soft, curved-edge paddle
  • Positioning
    Automated MLO positioning in a single click; ergonomic handles and face shield
  • Accessibility
    Retracts to its lowest height and inclines forward for wheelchair-bound patients
  • Image Output
    DICOM-compatible images with quick upload to hospital servers
  • Interface
    Feather-touch user interface
  • Intended settings
    Breast imaging centres and hospital radiology departments
  • Application
    Screening and diagnostic mammography
  • Warranty / Support
    Toll-free 1800-425-2355

Full technical specification sheet available on request.

See the Product in Use

  • Picture of Lilac Digital Mammography Clinical Setting
  • Picture of Lilac Digital Mammography Close Up
  • Picture of Lilac Digital Mammography Left Side View
  • Picture of Lilac Digital Mammography Right Side View
  • Lilac Digital Mammography
  • Picture of Lilac Digital Mammography Clinical Setting
  • Picture of Lilac Digital Mammography Close Up
  • Picture of Lilac Digital Mammography Left Side View
  • Picture of Lilac Digital Mammography Right Side View

Product Support You Can Depend On

Get product assistance, demo support, installation guidance, and service information directly from BPL Medical Technologies.

FAQs About Lilac Digital Mammography

This equipment serves as BPL's dedicated digital mammography system. It is used to capture high-quality, noise-free breast images. Medical staff rely on this for early cancer detection and precise diagonstic work.

Image acquisition with Lilac in typically takes 10 to 15 seconds.

Yes. The wide detector enables simultaneous screening of both breasts without increasing radiation dose.

Gridless technology in Lilac rejects scattered radiation without an anti-scatter grid, which reduces patient dose and improves image resolution.

Yes. The equipment physically drops to a very low height. It also tilts forward. This exact design keeps wheelchair patients perfectly comfortable during their screening.

Yes. The software naturally generates standard DICOM files. Technicians just upload these digital records straight to the existing hospital servers.

Screening works as a routine preventive exam. Doctors use it for patients showing zero symptoms. Diagnostic imaging serves a completely different purpose. Physicians specifically order it to investigate known issues, like a physical lump. That route requires much deeper detail. The Lilac handles both of these jobs easily.

Lilac functions as a completely brand-new digital mammography system out of the box. The RSM 2430C takes a different approach. It retrofits modern digital capabilities directly into an older existing mammography setup. Administrators simply need to decide whether they are installing fresh equipment from scratch or just upgrading their current hardware.